Sign In | Join Free | My entremaqueros.com |
|
Brand Name : CONSNANT
Model Number : CNS110
Certification : CE, ISO9001, ISO14001
Place of Origin : Shenzhen, China
MOQ : 10
Price : Negotiable
Payment Terms : 30% T/T inadvance, L/C, Western Union
Supply Ability : 50000 pieces per year
Delivery Time : 5-7 days for sample order, 7-15 days for mass production
Packaging Details : Each unit in one carton
Built in Solar Charge Controller : Yes
Wide DC Input Voltage : 80-270VAC
Selectable DC/AC Priority Function : Yes
AC Outpu : Single or Dual Output
Efficienc : (Battery Mode)≥87%; (Line Mode)
Nominal DC input Voltage : 24/48VDC
Transfer time : AC to DC: 20ms(max); DC to AC: 15ms(max)
1 - 6KW Hybrid Solar Power Inverter Off Grid With Generator Restart Signal
Different Features:
High frequency MPPT solar inverter solar hybrid inverter(Based on IGBT):
Low frequency MPPT solar inverter solar hybrid inverter(Based on Transformer):
Same Features:
Application:
CONSNANT 1-12kw power inverter off grid solar inverter hybrid inverter can work with solar energy, generator and AC mains. They are widely used for home appliances and office devices for long time backup.
CNS110 Series Technical Specifications:
Battery Inverter Mode Specifications: | |||
Output | Output Voltage | Sine wave | |
Rated Output | LV:1-6KW | HV:1KW-12KW | |
Power Factor | 0.9~1.0 | ||
Nominal Output | LV:120Vac±10% rms | HV:230 Vac±10% rms | |
Nominal Output | 60Hz±0.3Hz | ||
DC Voltage | Nominal DC | 12VDC/24VDC/48VDC | |
DC Voltage Range | 10-15.5Vdc for 12V battery | ||
20-31.0 Vdc for 24V battery | |||
40-62.0 Vdc for 48V battery | |||
Low Battery Alarm | 10.5Vdc±0.3Vdc for 12V Battery | ||
21.0 Vdc±0.6Vdc for24V Battery | |||
42.0 Vdc±1.2Vdc for 48V Battery | |||
Low DC | 10.0Vdc±0.3Vdc for 12V Battery | ||
20.0Vdc±0.6Vdc for 24V Battery | |||
40.0Vdc±1.2Vdc for 48V Battery | |||
High DC input alarm&fault | 16Vdc±0.3Vdc for 12V Battery | ||
32Vdc±0.6Vdc for 24V Battery | |||
64Vdc±1.2Vdc for 48V Battery | |||
High DC input recorvery | 15.5Vdc±0.3Vdc for 12V Battery | ||
31.0Vdc±0.6Vdc for 24V Battery | |||
62.0Vdc±1.2Vdc for 48V Battery | |||
AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5satges adjustable charging current) | |
Charge Current Regulation | ±5Adc | ||
Over Charge protection | Bat.V≧15.5VDC for 12V battery | ||
Bat.V≧31.0VDC for 24V battery | |||
Bat.V≧62.0VDC for48V battery | |||
Beeps 0.5s every 1s& fault after 60S | |||
Algorithm | |||
Three stage:Boost CC(Constant current stage) →Boost CV(Constant voltage stage) →Float(constant voltage stage) | |||
Solar Charger | Rated Charge Current | 40A | 60A |
Rated Charge Battery Voltage Type | 12V/24V/48V | 12V/24V | |
Max PV open Circuit array voltage | 12V for 40Vdc | ||
24V for 40Vdc | |||
48V for 110Vdc | |||
Charger Mode | MPPT | ||
PV Low Voltage Re-connect | PV≧Bat.V=3V | ||
PV Low Voltage Disconnect | PV≦Bat.V | ||
Efficiency | Efficiency | ≧97% | |
Efficiency(Battery Mode) | ≧85% | ||
Efficiency(Line Mode) | >98% | ||
Transfer Time | AC to DC | 20ms(Max) | |
DC to AC | 15ms(Max) | ||
System parameter | Over-load Protection | 110%<load<150%, beeps 0.5s every 1s, and fault after 60s off the output, | |
Surge rating(10s) | 1:3(VA) | ||
Power Saver | Load≦25W(enabled on “P/S auto” setting of Remote comtro;) | ||
Protections | Low battery, over charging, overload, over temp | ||
Indicatoers | LED+LCD Display | ||
General Specifications | Operation Temperature Range | 0℃ to 40℃ | |
Strorage Temperature | -15℃~60℃ | ||
Operation Humidity | 5% to 95%(non-condensing) | ||
Audible Noise | 60dB max | ||
Cooling | Forced air, Variable speed fan | ||
Dimension(L*W*H) | 1-3KW: 526*423*260mm | ||
Net Weight(Kg) | 1KW:21.5Kg; | 1.5KW:23.5Kg | |
3KW:30.5Kg | 4KW:32Kg | ||
5KW:36.5Kg | 6KW:40.5Kg | ||
7KW:43.5Kg | 8KW:50Kg | ||
10KW:57.5Kg | 12KW:60Kg |
![]() |
270VAC 1-6KW Hybrid Lithium Ion Ups Off Grid Solar Inverter 48VDC Images |