Brand Name : CONSNANT
Model Number : CNM330 -300K
Certification : CE, ISO9001, ISO14001
Place of Origin : Shenzhen, China
MOQ : 1 Unit
Price : Negotiable
Payment Terms : T/T, L/C, Western Union
Supply Ability : 500 pices per month
Delivery Time : 20days after receiving 30% deposit
Packaging Details : Wooden case
Inverter Output Voltage : 380/400/415VAC 3-phase 4-wire
Output Voltage Accuracy : ±0.5% ( balanced load ); ±1% ( unbalanced load )
Output Cap. Type : Large type
Application : data center, hospital, precision equipment, ISP, IDC
Equipment mode : Centralized model
Output Current Crest Ratio : 3:1
Hot Swapping Modular UPS System With Low THDi N + X Redundancy Design
High Availability Configuration Structure
Application:
Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.
Technical Specifications:
| Model | CNM330 20-300KVA | |
| Capacity | 20-300KVA | |
| Main Input | ||
| Input Voltage | 380V/400V/415V | |
| Input Frequency Range | 50/60Hz | |
| Power Factor | Full load>0.99 ,Half load >0.98 | |
| THDi | THDi<3% | |
| Input Power Soft-start Function | 5-30s settable | |
| Input Voltage Ranges | 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40% | |
| Frequency Range | 40-70HZ | |
| Battery | ||
| Battery Voltage | ±240VDC(Default),12V Battery 30~40pcs can be choose | |
| Charge Voltage Accuracy | ±1% | |
| Bypass | ||
| Bypass Input Voltage | 380/400/415VAC 3-phase 4-wire | |
| Voltage Range | Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software | |
| Overload Capacity | Long term at 135% rated load ,150%<load<180% more than 10 min, load>1000% 100ms | |
| Output | ||
| Inverter Output Voltage | 380/400/415VAC 3-phase 4-wire | |
| Voltage Accuracy | ±0.5% ( balanced load ) , ±1% ( unbalanced load ) | |
| THDV | THDV<1% (linear load) , THDV<3% (nonlinear load) | |
| Power Factor | 0.9 | |
| Three Phase Angle Accuracy | 120°± 0.5° | |
| Current Crest Ratio | 3:1 | |
| Overload Capacity | 110%1h,125%10mins,150%1mins,>150%200ms | |
| Transfer Time | 0ms,15ms (Eco Mode) | |
| System | ||
| Frequency | 50Hz/60Hz (Settable) | |
| Mains Synchronization Range | ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz | |
| Protection Level | IP20 | |
| Communication Ports | RS232,RS485,dry contact, SNMP card, EPO, generator port | |
| System efficiency | >96% at load above 50%, >95% at load above 25% | |
| Operation Temperature | 0-40ºC | |
| Storage Temperature | -25ºC~70ºC ( without battery) | |
| Humidity | 0-95% (no-condensing) | |
| Noise(dB) | 55-62dB,Adjusted with load | |
| Weight | module:PM20 | 20KVA power module : 30KG |
| module:PM30 | 30KVA power module : 35KG | |
| module:PM40 | 40KVA power module : 40KG | |
| Dimension (W x D x H)mm | 3 module cabinet | 600X900X1135 |
| 5 module cabinet(5 battery cabinet option) | 600X1100X2070/ | |
| 6 module cabinet | 600X900X1535 | |
| 10 module cabinet | 900X900X2080 | |
| power module | 440X650X132(3U)(10KVA/20KVA/30KVA) | |
(Optional South America 208V must be derating use)

|
|